THE EFFECT OF FREON-114 ON SPACE RECORDERS
Technical Report
·
OSTI ID:4206829
Space recorders are used at Goodyear Atomic Corporation to measure low concentrations of uranium hexafluoride in gas mixtures comprising essentially uranium hexafluoride and nitrogen. The calculations of the amount of uranium hexafluoride are based on the assumption that nitrogen is the only gas mixed with the uranium hexafluoride. The effect of the presence of Freon-114 in such a mixture was investigated in laboratory tests by replacing nitrogen with Freon-114. The tests indicate that Freon-114 produces more ion pairs than nitrogen per molecule, thus increasing the sensitivity of the space recorder. Also, it reduces the background radiation level resulting from residual contamination below that raeasured in the presence of nitrogen. The sensitivity increased almost linearly with an increase in Freon concentration. The ionization energy per ion pair for Freon-114 was calculated to be 7.0 plus or minus 0.7 electron volts. (auth)
- Research Organization:
- Goodyear Atomic Corp., Portsmouth, Ohio
- DOE Contract Number:
- AT-(33-2)-1
- NSA Number:
- NSA-13-020091
- OSTI ID:
- 4206829
- Report Number(s):
- GAT-232(Del.)
- Country of Publication:
- United States
- Language:
- English
Similar Records
PROCEDURE FOR MEASURING FREON 114 LEAK RATES IN CASCADE COOLANT CONDENSERS BY THE GAS DILUTION METHOD
REACTIONS OF FREON-114 WITH FLUORINE
SOLUBILITY OF NITROGEN IN FREON-114
Technical Report
·
Thu Aug 28 00:00:00 EDT 1958
·
OSTI ID:4303433
REACTIONS OF FREON-114 WITH FLUORINE
Technical Report
·
Wed May 14 00:00:00 EDT 1958
·
OSTI ID:4314941
SOLUBILITY OF NITROGEN IN FREON-114
Journal Article
·
Wed Dec 31 23:00:00 EST 1958
· Journal of Chemical and Engineering Data (U.S.)
·
OSTI ID:4262687