Armature current locus based estimation method of rotor position of permanent magnet synchronous motor without mechanical sensor

Conference ·
OSTI ID:419485

This paper describes a new method of estimating the initial rotor position of a permanent magnet (PM) motor without turning the rotor. At the stand still, the saliency of the PM motor makes the locus of the armature current-vector an oval when the armature voltage is 3-phase balanced sine wave applied by a PWM inverter. The major diameter direction of the current-vector locus gives an information on the rotor direction. The shift of the current-vector locus caused by magnetic saturation makes it possible to identify the direction of the rotor magnet N-pole. The proposed method to estimate the rotor position was verified by experimental results of a 100W PM motor.

OSTI ID:
419485
Report Number(s):
CONF-9510203--
Country of Publication:
United States
Language:
English

Similar Records

Servo drive system and control characteristics of salient pole permanent magnet synchronous motor
Journal Article · · IEEE Transactions on Industry Applications (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6304969

Indirect rotor position sensing in real time for brushless permanent magnet motor drives
Journal Article · Wed Jul 01 00:00:00 EDT 1998 · IEEE Transactions on Power Electronics · OSTI ID:665361

Analysis of field oriented control for permanent magnet hysteresis synchronous motors
Journal Article · · IEEE Transactions on Industry Applications (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:5053166