A PRECISE METHOD FOR DETERMINING VANADIUM IN ESSENTIALLY PURE VANADIUM METAL
Technical Report
·
OSTI ID:4190875
A method of analysis for vanadium in essentia1ly pure vanadium metal is presented. Precision resulting in a limit of error (0.95) for a single determination of plus or minus O.O79% is achieved by oxidizing the weighed and dissolved sample to vanadium(V) and reacting this solution with a weighed slight excess of ferrous ammonium sulfate hexahydrate. The excess reagent is then back- titrated with standard potassium dichromate solution, the titration representing less than 1% of the amount of vanadium present. (auth)
- Research Organization:
- Union Carbide Nuclear Co. Y-12 Plant, Oak Ridge, Tenn.
- DOE Contract Number:
- W-7405-ENG-26
- NSA Number:
- NSA-14-013688
- OSTI ID:
- 4190875
- Report Number(s):
- Y-1294
- Country of Publication:
- United States
- Language:
- English