Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

INITIAL EXPERIMENTS ON PRESSURE DROP FOR FLOW THROUGH ECCENTRIC ANNULI. Technical Note IX TN-1-59. PARTS I AND II

Technical Report ·
OSTI ID:4186938

The results of initial experiments on pressure drop in concentric and eccentric annuli with eccentricities up to 90% and a radius ratio of 1.5 are reported. The friction factor is correlated as a function of Reynolds number and eccentricity for both smooth and rough annuli. (W.L.H.)

Research Organization:
Columbia Univ., New York. Engineering Research Labs.
NSA Number:
NSA-14-010580
OSTI ID:
4186938
Report Number(s):
TID-5670
Country of Publication:
United States
Language:
English

Similar Records

HEAT TRANSFER AND PRESSURE DROP IN ECCENTRIC ANNULI
Technical Report · Sat Sep 30 00:00:00 EDT 1961 · OSTI ID:4816698

Non-Newtonian flow in eccentric annuli
Journal Article · Sat Sep 01 00:00:00 EDT 1990 · Journal of Energy Resources Technology; (USA) · OSTI ID:5888484

HEAT TRANSFER WITH TURBULENT FLOW IN CONCENTRIC AND ECCENTRIC ANNULI WITH CONSTANT AND VARIABLE HEAT FLUX
Thesis/Dissertation · Sun Dec 31 23:00:00 EST 1961 · OSTI ID:4760418