AN ULTRASONIC BOND TESTER FOR THE HANFORD CANNING LINE
Technical Report
·
OSTI ID:4180975
The ultrasonic tester and the frost test for insuring the metallurgical bonding of slugs are compared. The change from the triple dip to the lead dip method of canning caused more problems with the ultrasonic tester which is the more sensitive and consistent. Due to the high number of ultrasonic rejects and in view of the absence of pile performance data warranting a more costly approach, it has been decided that the ultrasonic rejects which pass the frost test will be considered safe for pile exposure. Circuits, photographs, data, and theory on the method are included. (M.H.R.)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- NSA Number:
- NSA-14-016878
- OSTI ID:
- 4180975
- Report Number(s):
- HW-39849
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
DEVELOPMENT OF ULTRASONIC UNBOND TEST
UT-4--AN AUTOMATIC ULTRASONIC TESTER FOR CLOSURES OF HANFORD I AND E FUELS
EDDY CURRENT AND ULTRASONIC TESTING OF CP-6 FUEL ELEMENTS
Technical Report
·
Tue Jun 22 00:00:00 EDT 1954
·
OSTI ID:4179514
UT-4--AN AUTOMATIC ULTRASONIC TESTER FOR CLOSURES OF HANFORD I AND E FUELS
Technical Report
·
Wed May 01 00:00:00 EDT 1963
·
OSTI ID:4680722
EDDY CURRENT AND ULTRASONIC TESTING OF CP-6 FUEL ELEMENTS
Technical Report
·
Mon Nov 30 23:00:00 EST 1953
·
OSTI ID:4216376