Title: DESIGN ANALYSIS OF A PREPACKAGED NUCLEAR POWER PLANT (1000 eKW). VOLUME I. PRIMARY AND SECONDARY SYSTEM DESIGN

Abstract

Reactor and primary and secondary system design analyses of a prepackaged nuclear power plant are presented. The plant is of the pressurized water steam-electric generating type which is air transportable skid mounted and suitable for a remote site installation. The plant design incorporates the maximum degree of reliability and simplicity and the minimum degree of maintenance and cost. The plant is capable of producing a gross electrical output of 1000 kw(e) and 5 x 10/sup 6/ Btu/hr for space heating. The primary system generates a total of 6.5 Mw of heat in order to supply the required electrical and heating load. (W.D.M.)

Publication Date:
Research Org.:
Alco Products, Inc., Schenectady, N.Y.
Sponsoring Org.:
US Atomic Energy Commission (AEC)
OSTI Identifier:
4177874
Report Number(s):
APAE-42(Vol.I)
NSA Number:
NSA-14-007123
DOE Contract Number:  
DA-44-009-ENG-3638
Resource Type:
Technical Report
Resource Relation:
Other Information: Orig. Receipt Date: 31-DEC-60
Country of Publication:
United States
Language:
English
Subject:
REACTOR TECHNOLOGY; ECONOMICS; ENVIRONMENT; HEATING; MAINTENANCE; PLANNING; POWER PLANTS; PRESSURE; WATER

Citation Formats

None. DESIGN ANALYSIS OF A PREPACKAGED NUCLEAR POWER PLANT (1000 eKW). VOLUME I. PRIMARY AND SECONDARY SYSTEM DESIGN. United States: N. p., 1959. Web. doi:10.2172/4177874.
None. DESIGN ANALYSIS OF A PREPACKAGED NUCLEAR POWER PLANT (1000 eKW). VOLUME I. PRIMARY AND SECONDARY SYSTEM DESIGN. United States. doi:10.2172/4177874.
None. Sun . "DESIGN ANALYSIS OF A PREPACKAGED NUCLEAR POWER PLANT (1000 eKW). VOLUME I. PRIMARY AND SECONDARY SYSTEM DESIGN". United States. doi:10.2172/4177874. https://www.osti.gov/servlets/purl/4177874.
@article{osti_4177874,
title = {DESIGN ANALYSIS OF A PREPACKAGED NUCLEAR POWER PLANT (1000 eKW). VOLUME I. PRIMARY AND SECONDARY SYSTEM DESIGN},
author = {None},
abstractNote = {Reactor and primary and secondary system design analyses of a prepackaged nuclear power plant are presented. The plant is of the pressurized water steam-electric generating type which is air transportable skid mounted and suitable for a remote site installation. The plant design incorporates the maximum degree of reliability and simplicity and the minimum degree of maintenance and cost. The plant is capable of producing a gross electrical output of 1000 kw(e) and 5 x 10/sup 6/ Btu/hr for space heating. The primary system generates a total of 6.5 Mw of heat in order to supply the required electrical and heating load. (W.D.M.)},
doi = {10.2172/4177874},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1959},
month = {2}
}