Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

NONDESTRUCTIVE TESTING OF B$sub 10$ SS POISON WIRE

Technical Report ·
OSTI ID:4176014
An investigation was made to determine if an eddy current technique could replace the dye penetrant test required on B/sub 10/ SS poison wire. Artificial and natural defects were evaluated on four types of eddy current equipment. The eddy current tests detected sub-surface voids and surface defects as small as 0.0030 in. deep and 0.0015 in. wide. The results showed that the eddy current test was not so sensitive to shallow surface defects as the dye test; however, the dye test could not detect sub-surface voids. (auth)
Research Organization:
Knolls Atomic Power Lab., Schenectady, N.Y.
DOE Contract Number:
W-31-109-ENG-52
NSA Number:
NSA-14-021769
OSTI ID:
4176014
Report Number(s):
KAPL-M-AJV-1
Country of Publication:
United States
Language:
English

Similar Records

NONDESTRUCTIVE TESTING OF SMALL TUBING
Journal Article · Wed Nov 30 23:00:00 EST 1960 · Metal Progr. · OSTI ID:4092998

Nondestructive examination of vessel bottom head penetrations
Conference · Fri Dec 30 23:00:00 EST 1994 · OSTI ID:72572

Properties of seamless steel pipes and nondestructive testing