PRECISION CAPACITOR DIVIDER METHOD FOR MEASURING HIGH VOLTAGES

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.1716410· OSTI ID:4171435
>A high-precision capacitor divider method for measuring the voltage on the terminal of a 2-Mv Van de Graaff accelerator is described, Calibration of the system was done using the Be( gamma ,n)threshold reaction. Linearity was tested using a total beam calorimeter and a beam current integrator. (auth)
Research Organization:
General Electric Co., Richland, Wash.
NSA Number:
NSA-14-008167
OSTI ID:
4171435
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 11 Vol. Vol: 30; ISSN 0034-6748
Country of Publication:
Country unknown/Code not available
Language:
English