FLOW COASTDOWN TEST. SECTION I. SECOND PERFORMANCE. CORE I, SEED I. Test Results DL-S-179 (T-612087)

Technical Report ·
OSTI ID:4171300

Studies were made to determine the rate of flow coastdown in the reactor coolant system upon loss of power to the reactor coolant pumps, The rate of now coastdown during the first three seconds after loss of power to the reactor coolant pumps was faster than predicted but was approximately the same as that observed during the first performance test. The flow coastdown characteristics for three pump operation was essentially the same as for four pump operation. Flow continued for approximately 28 seconds after shutdown of the reactor coolant pumpa. The 1D pump has a slower rate of flow coastdown than the 1B pump, but the maximum flow rate. of the 1D pump was less. (W.J.H.)

Research Organization:
Duquesne Light Co., Shippingport, Penna.
NSA Number:
NSA-14-012359
OSTI ID:
4171300
Report Number(s):
TID-5716
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

FLOW COASTDOWN TEST. SECTION 1. Test Results DL-S-179 (T-612087)
Technical Report · Thu Oct 16 00:00:00 EDT 1958 · OSTI ID:4279187

FLOW COASTDOWN TEST. CORE I, SEED 2. Test Results T-612087-A
Technical Report · Mon Jan 09 23:00:00 EST 1961 · OSTI ID:4072267

PRIMARY COOLANT FLOW COASTDOWN IN PWR CORE 1. Test Evaluation
Technical Report · Fri Mar 31 23:00:00 EST 1961 · OSTI ID:4715826