THE LIQUID ENTRAINMENT AND ITS REMOVAL FOR A LARGE SCALE EVAPORATION UNIT. EVAPORATION OF RADIOACTIVE LIQUID WASTE (in Japanese)
Journal Article
·
· J. Atomic Energy Soc. Japan
A large scale evaporation unit consisting of evaporator, cyclone, and packed tower was constructed, with which studies were made of the liquid entrainment and its removal. The results obtained are as follows: (1) the decontamination factor of the evaporator lies between 10/sup 4/ and 10/sup 5/; (2) that of the cyclone is in the range of 10 to 10/sup 2/; (3) the over-all decontamination factor of the evaporation unit lies between 10/sup 6/ and 10/sup 7/; (4) the optimum vapor mass velocity in the vapor space of the evaporator is about 2000 kg/m/sup 2/hr. With this optimum vapor mass velocity, the maximum over-all decontamination factor is obtained. The results obtained by the large scale evaporation unit were compared with that obtained by the small scale evaporation unit. (auth)
- Research Organization:
- Atomic Energy Research Inst., Tokyo; Univ. of Tokyo
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-14-008319
- OSTI ID:
- 4170412
- Journal Information:
- J. Atomic Energy Soc. Japan, Journal Name: J. Atomic Energy Soc. Japan Vol. Vol: 1
- Country of Publication:
- Country unknown/Code not available
- Language:
- Japanese
Similar Records
Decontamination Factor of a Radiochemical Waste Evaporator System
STUDIES ON TREATMENT OF RADIOACTIVE LIQUID WASTES BY FALLING FILM EVAPORATOR
Vapor/liquid interaction and entrainment in falling film evaporators
Journal Article
·
Wed Jan 31 23:00:00 EST 1962
· Nippon Genshiryoku Gakkai-Shi
·
OSTI ID:4795245
STUDIES ON TREATMENT OF RADIOACTIVE LIQUID WASTES BY FALLING FILM EVAPORATOR
Journal Article
·
Thu Oct 31 23:00:00 EST 1963
· Nippon Genshiryoku Gakkaishi (Japan)
·
OSTI ID:4128576
Vapor/liquid interaction and entrainment in falling film evaporators
Journal Article
·
Thu Jan 31 23:00:00 EST 1980
· J. Heat Transfer; (United States)
·
OSTI ID:5056395