Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

EFFICIENCY OF THE FILTERS AGAINST RADIOACTIVE AEROSOL. ON THE RADIOACTIVE CONTAMINATION AND ITS REMOVAL (in Japanese)

Journal Article · · Rodo Kagaku (Japan)
OSTI ID:4168844
Dust filters were examined using a radioactive solidaerosol, decay product daughters of Rn/sup 220/. An examination with a thermal precipitator revealed that the major part of particles in the radioactive aerosol were smaller than 0.5 mu in diameter. Twenty-one kinds of filters were tested. The filtering efficiency was highest in asbestos fiber filters. A radioautographic examination revealed that the radioactive substance penetrated as deep as 1.4 to 1.5 mm into the filter layer. (auth)