Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Nitrogen heat pipe for cryocooler thermal shunt

Conference ·
OSTI ID:416633
; ;  [1]
  1. Los Alamos National Lab., NM (United States); and others
A nitrogen heat pipe was designed, built and tested for the purpose of providing a thermal shunt between the two stages of a Gifford-McMahan (GM) cryocooler during cooldown. The nitrogen heat pipe has an operating temperature range between 63 and 123 K. While the heat pipe is in this temperature range during the system cooldown, it acts as a thermal shunt between the first and second stage of the cryocooler. The heat pipe increases the heat transfer to the first stage of the cryocooler, thereby reducing the cooldown time of the system. When the heat pipe temperature drops below the triple point, the nitrogen working fluid freezes, effectively stopping the heat pipe operation. A small heat leak between cryocooler stages remains because of axial conduction along the heat pipe wall. As long as the heat pipe remains below 63 K, the heat pipe remains inactive. Heat pipe performance limits were measured and the optimum fluid charge was determined.
OSTI ID:
416633
Report Number(s):
CONF-950722--
Country of Publication:
United States
Language:
English

Similar Records

Nitrogen heat pipe for cryocooler thermal shunt
Conference · Fri Sep 01 00:00:00 EDT 1995 · OSTI ID:106480

Heat pipes for enhanced cooldown of cyrogenic systems
Conference · Thu Aug 01 00:00:00 EDT 1996 · OSTI ID:279453

Gas - gap thermal switch for precooling of cryocooler-cooled superconducting magnets
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:416632