Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

13-WATT CURIUM-FUELED THERMOELECTRIC GENERATOR FOR HARD LUNAR IMPACT MISSION. Final Report-Subtask 5.8

Technical Report ·
DOI:https://doi.org/10.2172/4136544· OSTI ID:4136544
Results of a conceptual design study for a curium powered thermoelectric generator of minimum size and weight which is capable of sustaining hard impact is presented. The generator produces a minimum of 13 watts of d-c power at 3 volts, and weighs 6.2 pounds excluding shielding. (J.R.D.)
Research Organization:
Martin Co. Nuclear Div., Baltimore
Sponsoring Organization:
USDOE
DOE Contract Number:
AT(30-3)-217
NSA Number:
NSA-15-001943
OSTI ID:
4136544
Report Number(s):
MND-P-2374
Country of Publication:
United States
Language:
English

Similar Records

100-WATT CURIUM-242 FUELED THERMOELECTRIC GENERATOR--CONCEPTUAL DESIGN. SNAP Subtask 5.7 Final Report
Technical Report · Sun May 01 00:00:00 EDT 1960 · OSTI ID:4064170

ADVANCED THERMOELECTRIC POWER SYSTEM. Final Report
Technical Report · Thu Dec 31 23:00:00 EST 1959 · OSTI ID:4123121

Specification for strontium-90 500-watt(e) radioisotopic thermoelectric generator. Final report