ADDITIONAL SAFEGUARDS EVALUATION FOR THE U-Mo FUELED CORE OF THE HALLAM NUCLEAR POWER FACILITY

Technical Report ·
OSTI ID:4127986
Questions posed by the Reactor Hazards Evaluation Branch of the AEC upon review of supplement 1 to the report entitled Preliminary Safeguards Based on U- Mo Fuel for the Hallam Nuclear Power Facility (NAA-SR-3379) are answered in detail. Questions are included on loadingface shield leakage, primary-system confinement cells, NaO prefilter scrubber, fuel-handling incident, removal of dry water pipe lines, and steam generators. (W.D.M.)
Research Organization:
Atomics International. Div. of North American Aviation, Inc., Canoga Park, Calif.
NSA Number:
NSA-14-026456
OSTI ID:
4127986
Report Number(s):
NAA-SR-Memo-4067
Country of Publication:
United States
Language:
English

Similar Records

HNPF PRIMARY PIPE TUNNEL LEAK TEST REPORT
Technical Report · Thu Jan 18 23:00:00 EST 1962 · OSTI ID:4797422

ADDITIONAL SAFEGUARDS INFORMATION FOR HALLAM NUCLEAR POWER FACILITY
Technical Report · Tue Oct 31 23:00:00 EST 1961 · OSTI ID:4809632

PRELIMINARY SAFEGUARDS REPORT BASED ON URANIUM-MOLYBDENUM FUEL FOR THE HALLAM NUCLEAR POWER FACILITY
Technical Report · Mon Oct 30 23:00:00 EST 1961 · OSTI ID:4111595