OPERATIONAL CONTROL ROD REACTIVITY WORTHS FROM OBSERVED HEAT GENERATION RATES
Technical Report
·
OSTI ID:4121953
Control rod reactivity worths can be determined with reasonable accuracy from estimates of the neutron absorption rate in the rods and evaluation of the change in reactor leakage rate on rod withdrawal. In the Hanford reactors these values are found from measured control rod heat generation and reactor flux distribution data. This calibration technique can also be applied to reactors without separate rod-cooling systems. The neutron absorption rate in the rods is obtained from rod surface foil activation or activation of the rods themselves. The change in reactor leakage upon rod insertion is found with theoretical determinations of the unperturbed flux distribution andd the flux distribution after insertion of an equivalent control region. (auth)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-18-006417
- OSTI ID:
- 4121953
- Report Number(s):
- CONF-243-34
- Country of Publication:
- United States
- Language:
- English
Similar Records
PT-N-336: N Reactor rod calibration
WORTHS OF BLACK CONTROL RODS
PERTURBATION THEORY CONTROL ROD WORTH
Technical Report
·
Tue Oct 29 23:00:00 EST 1974
·
OSTI ID:6768001
WORTHS OF BLACK CONTROL RODS
Journal Article
·
Fri Feb 28 23:00:00 EST 1958
· Nuclear Sci. and Eng.
·
OSTI ID:4335481
PERTURBATION THEORY CONTROL ROD WORTH
Technical Report
·
Fri Nov 30 23:00:00 EST 1956
·
OSTI ID:4337696