A channel electron multiplier has been used for counting ionized clusters containing up to a few thousands molecules; clusters are accelerated towards a negative (approximately-220V) copper target; a larger negative bias (approximately-3000V) is applied to the multiplier entrance so as to collect positive secondary ions and/or reflected cluster fragments; in the present application this gives better signal to noise ratio than detecting clusters directly or by secondary electron emission on the target. (FR)