THE DETERMINATION OF COMBINED CARBON IN BERYLLIUM METAL (BY IGNITION WITH A GASOMETRIC FINISH)

Technical Report ·
OSTI ID:4107095
The beryllium sample is dissolved in H/sub 2/S0/sub 4/, and the evolved gases (methane and hydrogen) are passed over copper oxide at 850 ts C. The water produced is removed, and the carbon dioxide is measured by a gasometric finish. The lower limit of carbon detection is 30 ppm. (auth)
Research Organization:
United Kingdom Atomic Energy Authority. Industrial Group. Springfields Works, Springfields, Lancs, England
NSA Number:
NSA-15-008670
OSTI ID:
4107095
Report Number(s):
IGO-AM/S-151(2nd. ed.)
Country of Publication:
Country unknown/Code not available
Language:
English