THE DETERMINATION OF COMBINED CARBON IN BERYLLIUM METAL (BY IGNITION WITH A GASOMETRIC FINISH)
Technical Report
·
OSTI ID:4107095
The beryllium sample is dissolved in H/sub 2/S0/sub 4/, and the evolved gases (methane and hydrogen) are passed over copper oxide at 850 ts C. The water produced is removed, and the carbon dioxide is measured by a gasometric finish. The lower limit of carbon detection is 30 ppm. (auth)
- Research Organization:
- United Kingdom Atomic Energy Authority. Industrial Group. Springfields Works, Springfields, Lancs, England
- NSA Number:
- NSA-15-008670
- OSTI ID:
- 4107095
- Report Number(s):
- IGO-AM/S-151(2nd. ed.)
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
THE DETERMINATION OF COMBINED CARBON IN BERYLLIUM METAL (BY IGNITION WITH A GASOMETRIC FINISH)
THE DETERMINATION OF FREE CARBON IN BERYLLIUM METAL (BY IGNITION WITH A GASOMETRIC FINISH)
THE DETERMINATION OF FREE CARBON IN BERYLLIUM METAL (BY IGNITION WITH A GASOMETRIC FINISH)