Calibration of the SRE Shim Rods by the Oscillation Method
- North American Aviation, Inc., Canoga Park, CA (United States). Atomics International Div.
Calibrations of the SRE shim rods were obtained by oscillation and period methods. The oscillation and period measurements compared within a scatter of 6% of mean differential worth. Three different oscillation techniques were employed: 1) Direct oscillation of a shim rod by means of a Scotch-yoke mechanical drive. 2) Direct oscillation of a shim rod by use of the existing relay servo controller. 3) Inserting a known step change of reactivity by rotating a rotary oscillator and observing the change in shim rod position as commanded by the automatic flux controller. Period measurements were performed following the oscillation measurements of each point. The time required for oscillation measurements was less than one-fifth that required for period measurements. Oscillation measurements were shown to have an accuracy equal to or better than period measurements. Oscillation measurements performed at power proved this technique of shim rod calibration to be applicable from zero to any desired power level. This is because the average power level of the reactor is unaffected by the oscillation method of calibration.
- Research Organization:
- North American Aviation, Inc., Canoga Park, CA (United States). Atomics International Div.
- Sponsoring Organization:
- US Atomic Energy Commission (AEC)
- DOE Contract Number:
- AT(11-1)-GEN-8
- NSA Number:
- NSA-15-004757
- OSTI ID:
- 4097225
- Report Number(s):
- NAA-SR--3764
- Country of Publication:
- United States
- Language:
- English
Similar Records
CONTROL ROD CALIBRATIONS FOR THE SRE WITH THORIUM-URANIUM FUEL
MTR SHIM ROD CALIBRATIONS
EXPERIENCE WITH THE USE OF THE ROD-DROP METHOD OF ROD CALIBRATION AT THE ORR AND LITR
Technical Report
·
Fri Jun 01 00:00:00 EDT 1962
·
OSTI ID:4823214
MTR SHIM ROD CALIBRATIONS
Technical Report
·
Tue Sep 19 00:00:00 EDT 1961
·
OSTI ID:4826908
EXPERIENCE WITH THE USE OF THE ROD-DROP METHOD OF ROD CALIBRATION AT THE ORR AND LITR
Technical Report
·
Thu Aug 01 00:00:00 EDT 1963
·
OSTI ID:4674067