Influence of dosimetry on earlier damage equivalence ratios
Conference
·
· IEEE Trans. Nucl. Sci., v. NS-22, no. 6, pp. 2336-2339
OSTI ID:4094876
Since it was first noted that the experimental damage equivalence ratios for different neutron spectra obtained from change in transistor parameter behavior did not agree with the calculated ratios based on damage to silicon, an explanation has been sought for this apparent discrepancy. Investigations have included device processing techniques device geometry, and finally dosimetry. Careful dosimetry is of the utmost importance to these ratio measurements. Recently extensive studies of the White Sands Fast Burst Reactor (FBR), which is identical to the Sandia Pulsed Reactor (SPR-II), yielded information which suggested that a significant error was possible in the SPR-II dosimetry utilized in earlier studies. A test group at SA1726 (2N4251) transistors were used to make a comparison of the spectrum from the FBR and the SPR-II. The results of the device study showed a difference of 25-30 percent in fluence measured by Sandia dosimetry and by White Sands dosimetry for a given FBR exposure. This difference was for a 10 keV energy threshold. These findings prompted an investigation of the Sandia dosimetry techniques used at SPR-II. This investigation showed, on the basis of dosimetry measurements excluding fission foils, that the 10 keV/3 MeV ratio for SPR-II was 7.5 instead of 10 as presently used. The correction in dosimetry from SPR-II when applied to earlier damage equivalence ratios changes the 14 MeV-to-SPR-II damage ratio from 4.2 to approximately 2.9. This value (2.9) is in good agreement with other experimenters and calculations based on displacement damage in silicon. (auth)
- Research Organization:
- Sandia Labs., Albuquerque, NM
- NSA Number:
- NSA-33-020332
- OSTI ID:
- 4094876
- Conference Information:
- Journal Name: IEEE Trans. Nucl. Sci., v. NS-22, no. 6, pp. 2336-2339
- Country of Publication:
- United States
- Language:
- English
Similar Records
Correlation of radiation damage in solid state devices to neutron spectral characteristics
Simultaneous neutron spectrum and transistor-damage measurements in diverse neutron fields: Validity of D sub si (e sub n). Final report, 24 January 1977-12 September 1978
Estimation of 1-MeV equivalent neutron fluence from dosimetry response without spectrum unfolding
Conference
·
Wed Nov 30 23:00:00 EST 1977
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:6506270
Simultaneous neutron spectrum and transistor-damage measurements in diverse neutron fields: Validity of D sub si (e sub n). Final report, 24 January 1977-12 September 1978
Technical Report
·
Thu Mar 15 23:00:00 EST 1979
·
OSTI ID:5570328
Estimation of 1-MeV equivalent neutron fluence from dosimetry response without spectrum unfolding
Conference
·
Wed Nov 30 23:00:00 EST 1994
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:6559002
Related Subjects
*TRANSISTORS-- PHYSICAL RADIATION EFFECTS
440200* --Instrumentation--Radiation Effects on Instrument Components
Instruments
or Electronic Systems
DOSIMETRY
ERRORS
FBR TYPE REACTORS
N46300* --Instrumentation--Radiation Effects on Instrument Components
Instruments
or Electronic Systems
SILICON
SPR-2 REACTOR
440200* --Instrumentation--Radiation Effects on Instrument Components
Instruments
or Electronic Systems
DOSIMETRY
ERRORS
FBR TYPE REACTORS
N46300* --Instrumentation--Radiation Effects on Instrument Components
Instruments
or Electronic Systems
SILICON
SPR-2 REACTOR