ILLUMINATION OF 80$sub 4$ CHAMBER
The needed illumination intensity is estimated from the 20-in. and 72- in. chambers to be 50 and 160 lumen-sec/ft/sup 2/ respectively. Possible source distributions are considered. With in intensity of 100 lumen-sec/ft/sup 2/ and a source brightness of 100 lumen-sec/ster. cm/sup 2/, the aperture is calculated to have a diameter of 8.6 cm. (D.L.C.)