Fast-response thermocouple for temperature fluctuation measurements in sodium coolants
Journal Article
·
· Nucl. Technol., v. 27, no. 3, pp. 523-525
A special Chromel/Alumel thermocouple was fabricated whereby the bare ends of the wires were fixed 1 mm apart. In a medium with a good electrical conductivity (e.g., liquid sodium), the junction of the thermocouple is replaced by the medium itself. Hence, a fast undelayed response is expected. While mean temperature data of the device are in good agreement with data for conventional thermocouples, power spectral densities of the open element contain contributions from much higher frequencies than those of conventional thermocouples. (auth)
- Research Organization:
- Institut fuer Reaktortechnik, Wuerenlingen, Switzerland
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-33-022106
- OSTI ID:
- 4062280
- Journal Information:
- Nucl. Technol., v. 27, no. 3, pp. 523-525, Journal Name: Nucl. Technol., v. 27, no. 3, pp. 523-525; ISSN NUTYB
- Country of Publication:
- United States
- Language:
- English
Similar Records
CALIBRATION OF OMRE FUEL-ELEMENT SURFACE THERMOCOUPLE ASSEMBLY
LIMITATIONS IN THE USE OF THERMOCOUPLES FOR TEMPERATURE MEASUREMENTS IN MAGNETIC FIELDS
Effects of fast-neutron irradiation on sheathed Chromel/Alumel thermocouples
Technical Report
·
Wed Mar 11 23:00:00 EST 1959
·
OSTI ID:4222649
LIMITATIONS IN THE USE OF THERMOCOUPLES FOR TEMPERATURE MEASUREMENTS IN MAGNETIC FIELDS
Journal Article
·
Sun Dec 31 23:00:00 EST 1961
· Temp. Meas. Control Sci. Ind.
·
OSTI ID:4674516
Effects of fast-neutron irradiation on sheathed Chromel/Alumel thermocouples
Technical Report
·
Sun Aug 01 00:00:00 EDT 1976
·
OSTI ID:7267723