ANALYTICAL METHOD FOR THE FLUORIMETRIC DETERMINATION OF TRACE AMOUNTS OF URANIUM IN EFFLUENT TREATMENT PLANT SOLUTIONS
Technical Report
·
OSTI ID:4047263
The sample is evaporated to dryness, the residue fused with a sodium fluoride/sodium bicarbonate mixture and the uranium is measured fluorimetrically. The method is suitable for the determination of uranium in samples from the effluent treatment plant. (auth)
- Research Organization:
- United Kingdom Atomic Energy Authority. Production Group, Windscale, Sellafield, England
- NSA Number:
- NSA-15-022250
- OSTI ID:
- 4047263
- Report Number(s):
- PG-Report-200
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
ANALYTICAL METHODS FOR THE DETERMINATION OF URANIUM IN URINE
ANALYTICAL METHOD FOR THE DETERMINATION OF PARTICULATE URANIUM ON ATMOSPHERIC DUST ADHESION PLATES (FLUORIMETRIC METHOD)
FIELD LABORATORY METHODS FOR THE DETERMINATION OF URANIUM IN NON-SALINE WATERS
Technical Report
·
Wed Dec 31 23:00:00 EST 1958
·
OSTI ID:4180583
ANALYTICAL METHOD FOR THE DETERMINATION OF PARTICULATE URANIUM ON ATMOSPHERIC DUST ADHESION PLATES (FLUORIMETRIC METHOD)
Technical Report
·
Sat Dec 31 23:00:00 EST 1960
·
OSTI ID:4023401
FIELD LABORATORY METHODS FOR THE DETERMINATION OF URANIUM IN NON-SALINE WATERS
Technical Report
·
Fri Oct 31 23:00:00 EST 1958
·
OSTI ID:4266839