HEAT TRANSFER BURNOUT OF A SURFACE CONTACTED BY A SPACER RIB
Technical Report
·
OSTI ID:4042866
Measurements showed that the burnout heat flux of surfaces locally insulated by vertical ribs and cooled by downward flowing water was as much as 32% lower than the burnout heat flux of surfaces without ribs. The results of the tests were correlated by an equation that includes the effects of the themal conductivity and thickness of the heated surface, the width of the rib tip, and the clearance between the rib tip and the heated surface. (auth)
- Research Organization:
- Du Pont de Nemours (E.I.) & Co. Savannah River Lab., Aiken, S.C.
- NSA Number:
- NSA-15-022422
- OSTI ID:
- 4042866
- Report Number(s):
- DP-562
- Country of Publication:
- United States
- Language:
- English
Similar Records
Burnout heat flux with rib contact
Burnout heat flux with rib contact
ROUGHENING OF HEAT TRANSFER SURFACES AS A METHOD OF INCREASING HEAT FLUX AT BURNOUT
Technical Report
·
Mon Mar 05 23:00:00 EST 1973
·
OSTI ID:5790511
Burnout heat flux with rib contact
Technical Report
·
Mon Mar 05 23:00:00 EST 1973
·
OSTI ID:6343285
ROUGHENING OF HEAT TRANSFER SURFACES AS A METHOD OF INCREASING HEAT FLUX AT BURNOUT
Technical Report
·
Wed Dec 31 23:00:00 EST 1958
·
OSTI ID:4017145