DESIGN EVALUATION AND COMPARISON 200 MWe BOILING D$sub 2$O PRESSURE TUBE INDIRECT AND DIRECT CYCLE POWER REACTOR PLANTS
Technical Report
·
OSTI ID:4041703
The engineering and economics of 200-Mwe D/sub 2/Omoderated power reactor plants were evaluated for both direct and indirect cycles with boiling D/ sub 2/O-cooled pressure tube reactors. Comparison of the cost estimates indicates that the reduction in cost due to smaller D/sub 2/O inventory in the turbine plant in the indirect cycle does not offset the additional cost of the steam generators and preheaters. The cost difference of 0.1 mill/kwh power between the two cycles indicates that the two cycles are essentially economically equivalent. (D.L.C.)
- Research Organization:
- Sargent and Lundy, Chicago; and Nuclear Development Corp. of America, White Plains, N.Y.
- NSA Number:
- NSA-15-015287
- OSTI ID:
- 4041703
- Report Number(s):
- NDA-2131-6; SL-1776
- Country of Publication:
- United States
- Language:
- English
Similar Records
HEAVY-WATER-MODERATED POWER REACTORS ENGINEERING AND ECONOMIC EVALUATIONS. VOLUME I. SUMMARY REPORT
CANDU TO UNDERSELL COAL BY 1 MILL IN '70s
CIVILIAN POWER REACTOR PROGRAM. PART III. STATUS REPORT ON LARGE (100 AND 300 MWe) HEAVY WATER-MODERATED POWER REACTORS--AS OF 1960
Technical Report
·
Wed Jun 01 00:00:00 EDT 1960
·
OSTI ID:4133696
CANDU TO UNDERSELL COAL BY 1 MILL IN '70s
Journal Article
·
Mon Dec 31 23:00:00 EST 1962
· Canadian Nuclear Technology (Canada) Superseded by Can. Res. Dev.
·
OSTI ID:4686177
CIVILIAN POWER REACTOR PROGRAM. PART III. STATUS REPORT ON LARGE (100 AND 300 MWe) HEAVY WATER-MODERATED POWER REACTORS--AS OF 1960
Technical Report
·
Fri Aug 19 00:00:00 EDT 1960
·
OSTI ID:4789688