Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

GENERAL ELECTRIC VALLECITOS BOILING WATER REACTOR. Final Hazards Summary Report

Technical Report ·
OSTI ID:4007513
Descriptions and evaluations are included of modifications to be made to the VBWR installation to obtain information contributing to the development of safer, more efficient and more economical boiling-water reactor power plants. Sufficient changes are proposed that the accident analyses have of necessity changed from those of previous editions, but analyses of the maximum credible accident and other severe hypothetical accidents are essentially unchanged. Other changes made reflect changes in plant design and procedures resulting from the modifications. All pertinent information describing the VBWR is consolidated including technical specifications, process description, facility description, instrumentation, operating procedures, site characteristics and description, safety analysis, waste disposal, and special experimental facilities. (B.O.G.)
Research Organization:
General Electric Co. Vallecitos Atomic Lab., San Jose, Calif.
NSA Number:
NSA-15-019035
OSTI ID:
4007513
Report Number(s):
SG-VAL-2(3rd Ed.)
Country of Publication:
Country unknown/Code not available
Language:
English