DESIGN TEST 1172--THERMAL AND BENDING TEST OF GRAYLOC CONNECTION FOR ARCO ATR GAS LOOP
Technical Report
·
OSTI ID:4005189
The ability of a modified Grayloc connector to contain He at pressure and temperature was tested, since such connectors will be welded to a stainless steel tube containing He at 280 psi and 600 deg F. The connector was cyclically subjected to a bending moment of 400 ft-lb, heated to 600 deg F as the bending moment was removed, vibrated at 270 cpm at 600 deg F, and cooled to 200 deg F as bending moment was reapplied. The results are discussed. (D.C.W.)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-18-021681
- OSTI ID:
- 4005189
- Report Number(s):
- HW-80680
- Country of Publication:
- United States
- Language:
- English