Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Performance of the beam position monitor for the Advanced Photon Source

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.1146860· OSTI ID:389584
;  [1]
  1. Accelerator Systems Division, Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)
Performance measurement and analysis of the Advanced Photon Source (APS) beam position monitor (BPM) electronics are reported. The results indicate a BPM resolution of 0.16 {mu}m{center_dot}mA/{radical}Hz in terms of the single-bunch current and BPM bandwidth. For the miniature insertion device (ID) BPM, the result was 0.1 {mu}m{center_dot}mA/{radical}Hz. The improvement is due to the 3.6 times higher position sensitivity (in the vertical plane), which is partially canceled by the lower button signal by a factor of 2.3. The minimum single-bunch current required was roughly 0.03 mA. The long-term drift of the BPM electronics independent of the actual beam motion has measured at 2 {mu}m/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Implications of the BPM resolution limit on the global and local orbit feedback systems for the APS storage ring will also be discussed. {copyright} {ital 1996 American Institute of Physics.}
Research Organization:
Argonne National Laboratory (ANL), Argonne, IL
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
389584
Report Number(s):
CONF-9510119--
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 9 Vol. 67; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Similar Records

Resolution and drift measurements on the Advanced Photon Source beam position monitors
Conference · Mon Oct 31 23:00:00 EST 1994 · OSTI ID:10194600

Commissioning results of the APS storage ring RF beam position monitors
Journal Article · Tue Dec 31 23:00:00 EST 1996 · AIP Conference Proceedings · OSTI ID:526806

Resolution and drift measurements on the advanced photon source beam position monitor
Journal Article · Fri May 05 00:00:00 EDT 1995 · AIP Conference Proceedings · OSTI ID:249321