Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Macromolecular crystallographic results obtained using a 2048{times}2048 CCD detector at CHESS

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.1147503· OSTI ID:389564
; ; ; ;  [1]
  1. Section of Biochemistry, Cell and Molecular Biology, Cornell University, Ithaca, NY 14853 (United States)

We present results of macromolecular crystallographic experiments performed at the Cornell High Energy Synchrotron Source (CHESS) with a new CCD-based detector. This detector, installed in January 1995, complements a 1024{times}1024 CCD detector that has been in continuous operation at CHESS since December 1993. The new detector is based on a 4-port, 2048{times}2048 pixel CCD that is directly coupled to a Gd{sub 2}O{sub 2}S:Tb phosphor by a 3:1 tapered fiber optic. The active area of the phosphor is a square 82 mm on an edge. The readout time is 7 seconds. In the standard mode of operation, the pixel size at the active area is 41 {mu}m on the edge leading to the capability of resolving approximately 200 orders of diffraction across the detector face. The detector also operates in a 1024{times}1024 mode in which the pixel size is electronically increased by a factor of 4 in area resulting in smaller data files and faster detector readout but at the expense of spatial resolution. Most of the data that has been collected by this detector has been collected in this mode. Dozens of data sets have been collected by many experimenters using this detector at CHESS during the four month period from its installation until the start of the six-month down period of the storage ring. The capabilities of the detector will be illustrated with results from various crystallographic measurements including experiments in which the recorded diffraction patterns extend in resolution as far as 1 A. The results demonstrate that this detector is capable of collecting data of quality at least equal to that of imaging plates but, in many circumstances, with much greater beamline efficiency. {copyright} {ital 1996 American Institute of Physics.}

DOE Contract Number:
FG02-87ER60522
OSTI ID:
389564
Report Number(s):
CONF-9510119--
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 9 Vol. 67; ISSN RSINAK; ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Macromolecular crystallographic results obtained at CHESS using a detector incorporating a charge-coupled device
Journal Article · Tue Jan 31 23:00:00 EST 1995 · Review of Scientific Instruments; (United States) · OSTI ID:6575932

X-ray area detector based on CCD readout for diffraction study (abstract)
Journal Article · Tue Dec 31 23:00:00 EST 1991 · Review of Scientific Instruments; (United States) · OSTI ID:5520103

A 100 % Duty-ratio 3 x 6 Arrayed CCD X-ray Detector for Rapid Data Collection in Macromolecular Crystallography
Journal Article · Wed May 12 00:00:00 EDT 2004 · AIP Conference Proceedings · OSTI ID:20653103