Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Cone penetrometer moisture probe acceptance test report

Technical Report ·
DOI:https://doi.org/10.2172/362386· OSTI ID:362386

This Acceptance Test Report (ATR) documents the results of WHC-SD-WM-ATP-146 (Prototype Cone Penetrometer Moisture Probe Acceptance Test Procedure) and WHC-SD-WM-ATP-145 (Cone Penetrometer Moisture Probe Acceptance Test Procedure). The master copy of WHC-SD-WM-ATP-145 can be found in Appendix A and the master copy of WHC-SD-WM-ATP-146 can be found in Appendix B. Also included with this report is a matrix showing design criteria of the cone penetrometer moisture probe and the verification method used (Appendix C).

Research Organization:
Fluor Daniel Hanford Inc., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
362386
Report Number(s):
WHC-SD-WM-ATR--145; ON: DE99050403; BR: EW3120074
Country of Publication:
United States
Language:
English

Similar Records

Cone penetrometer moisture probe acceptance test procedure
Technical Report · Sun Dec 31 23:00:00 EST 1995 · OSTI ID:464353

Cone penetrometer acceptance test report
Technical Report · Thu Sep 19 00:00:00 EDT 1996 · OSTI ID:658907

Acceptance test report for the safety class shutdown system