Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Case study of selective catalytic reduction system start-up on digester gas fired combustion turbines

Conference ·
OSTI ID:351162
; ;  [1]
  1. County Sanitation Districts of Los Angeles County, Whittier, CA (United States)
In August 1989, the South Coast Air Quality Management District (SCAQMD) adopted Rule 1134 which imposed strict NO{sub x} emission limits on stationary, non-utility, combustion turbines. The rule was technology-forcing for the owners and operators of digester gas fired combustion turbines since it established a NO{sub x} emission limit of 9 parts per million by volume at 15 percent oxygen. The County Sanitation Districts of Los Angeles County (Districts), operators of three 6.5 MW digester gas fired turbines, elected to retrofit the turbines with selective catalytic reduction (SCR) systems to achieve compliance with the SCAQMD rule. After four years and costs in excess of four million dollars, the Districts continue to work on achieving system performance goals. This case study provides a brief history of the development of Rule 1134 and the motivation behind the strict NO{sub x} limits. The Districts` rationale in choosing SCR systems as a means of attaining compliance is presented along with a discussion of the physical site constraints which resulted in a less than optimum retrofit installation of the SCR systems. SCR system performance problems are examined including what was suspected to be poisoning of the catalyst by potassium in the turbine exhaust gas. The major actions undertaken by the Districts, its contractor and subcontractors to bring the turbines into compliance are also presented including optimizing exhaust flow distribution through the catalyst reactor, optimizing the ammonia mixing in the exhaust duct, optimizing water injection rates, installing intake combustion air evaporative cooling systems, reactivating the catalyst with resistant coatings, and undertaking structural retrofits to prevent distortion of the reactor house caused by thermal expansion. The case study concludes with a brief summary of the SCR systems` final physical configuration and performance and an update on the pending regulation changes.
OSTI ID:
351162
Report Number(s):
CONF-970677--
Country of Publication:
United States
Language:
English

Similar Records

Application of selective catalytic reduction systems for NO sub x control
Conference · Sun Dec 31 23:00:00 EST 1989 · Proceedings of the American Power Conference; (United States) · OSTI ID:6176488

Selective catalytic reduction impact on heat recovery steam generator design and operation
Conference · Tue Dec 31 23:00:00 EST 1985 · OSTI ID:5053074

Districts minimize energy costs with digester gas
Journal Article · Wed Feb 28 23:00:00 EST 1979 · J. Water Pollut. Control Fed.; (United States) · OSTI ID:5669574