Evaluation of five simple ventilation strategies suitable for houses without forced-air heating

Conference ·
OSTI ID:345273
;  [1]
  1. National Research Council, Ottawa, Ontario (Canada). Building Performance Lab.

Houses without forced-air heating systems may not experience adequate distribution of their outdoor air supply. This project examined five simple ventilation systems suitable for such houses. Four were exhaust-only, using either only local exhaust fans in the kitchen and bathrooms or the local exhaust fans supplemented with a partially distributed exhaust system with pickups in each bedroom. Each approach was tested with deliberate passive inlet vents (both distributed and centralized) both open and closed. The fifth system was a supply and exhaust system with small-sized ducts supplying outdoor air to each room and the local exhaust fans providing the exhaust. The five ventilation systems were installed in a two-story house that also has an electric forced-air heating system. Using tracer gas techniques, the air distribution patterns provided by each system for a wide range of weather conditions were measured and compared with similar reference measurements in the house with no mechanical air exchange with the outdoors and with only the forced-air furnace fan operating to circulate the air within the house. The local exhaust fan system with no passive inlet vents was found to provide inadequate distribution of the outdoor air supply, only marginally better than simple air leakage alone. With the distributed passive inlet vents open, the local exhaust fan system was found to distribute more outdoor air to the ground-floor rooms than the upper-story bedrooms. The partially distributed exhaust system was effective at improving the ventilation air distribution to the bedrooms. The minimal ducted supply system provided the best outdoor air distribution to all the habitable rooms.

OSTI ID:
345273
Report Number(s):
CONF-9702141--
Country of Publication:
United States
Language:
English

Similar Records

Tracer gas test in Net-Zero Energy Residential Test Facility
Technical Report · Mon Jun 01 00:00:00 EDT 2020 · OSTI ID:1648892

Modeling study of ventilation, IAQ and energy impacts of residential mechanical ventilation
Technical Report · Fri May 01 00:00:00 EDT 1998 · OSTI ID:638567

Energy recovery ventilator
Patent · Tue Apr 30 00:00:00 EDT 1985 · OSTI ID:5237244