DARHT Axis 1 Bremsstrahlung Dose Measurements

Technical Report ·
DOI:https://doi.org/10.2172/2999889· OSTI ID:2999889

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation
DOE Contract Number:
89233218CNA000001
OSTI ID:
2999889
Report Number(s):
LA-UR--25-25325
Country of Publication:
United States
Language:
English

Similar Records

DARHT Axis 1 Time-Resolved Injector Energy Measurement
Technical Report · Mon Aug 03 00:00:00 EDT 2020 · OSTI ID:1645060

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements
Technical Report · Mon Feb 15 23:00:00 EST 2021 · OSTI ID:1765860

DARHT Axis 1 Performance Results with and without a Blumlein Charge Unit
Technical Report · Mon Aug 03 00:00:00 EDT 2020 · OSTI ID:1645068