DARHT Axis 1 Performance Results with and without a Blumlein Charge Unit

Technical Report ·
DOI:https://doi.org/10.2172/1645068· OSTI ID:1645068
The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis 1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. As DARHT Axis 1 enters its twentieth year of operation, the probability of Blumlein Charge Unit (BCU) failure has increased and the risk of a failure on the day of an explosive experiment has become more likely. Replacement time for a BCU is four to six hours. This report examines the radiographic and beam transport effect of operating the accelerator with a missing or reduced charge voltage BCU. The results are compared with normal, full machine operation. A prescription for alternate operation with missing or reduced charge voltage on BCU22 is given.
Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Programs (DP)
DOE Contract Number:
89233218CNA000001
OSTI ID:
1645068
Report Number(s):
LA-UR--20-25852
Country of Publication:
United States
Language:
English

Similar Records

Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer
Technical Report · Tue Oct 08 00:00:00 EDT 2019 · OSTI ID:1569726

Optimization of DARHT Axis 1 Injector Voltage
Technical Report · Thu Aug 13 00:00:00 EDT 2020 · OSTI ID:1648059

DARHT Axis 1 Time-Resolved Injector Energy Measurement