Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Distributed measurement of conductor temperatures in mine trailing cables using fiber-optic technology

Journal Article · · IEEE Transactions on Industry Applications
DOI:https://doi.org/10.1109/28.663485· OSTI ID:290098
; ;  [1];  [2]
  1. National Inst. for Occupational Safety and Health, Pittsburgh, PA (United States). Research Lab.
  2. AmerCable, Sewickley, PA (United States)
Mine trailing cables operated above safe thermal limits can cause premature insulation failure, increasing electrocution and fire hazards. Previous US Bureau of Mines Pittsburgh Research Center research showed that, under static test conditions, electrical current levels permitted under present regulations may not limit cable temperatures to less than the 90 C rating of reeled trailing cable. Continuing research under the National Institute for Occupational Safety and Health (NIOSH) addresses thermal characteristics of reeled trailing cable under dynamic test conditions more representative of field conditions, where operators constantly reel in and pay out cable. This research is in support of efforts by industry associations and the Mine Safety and Health Administration to establish safety guidelines for cyclically rated reeled machines. This paper describes a unique approach to measuring temperatures within reeled cable under dynamic test conditions. Fiber-optic sensors embedded within the metallic conductors measure temperatures at 1-m intervals along the entire length of cable. Temperature measurements are reported to be accurate to within {+-}1 C. The test setup requires access to only one end of the trailing cable, allowing researchers to freely reel in and pay out cable while temperature measurements are made, simulating field conditions. Manufacture of a fiber-optic-embedded trailing cable is described, along with initial test results that indicate the fiber-optic approach is viable.
OSTI ID:
290098
Report Number(s):
CONF-961096--
Journal Information:
IEEE Transactions on Industry Applications, Journal Name: IEEE Transactions on Industry Applications Journal Issue: 2 Vol. 34; ISSN 0093-9994; ISSN ITIACR
Country of Publication:
United States
Language:
English

Similar Records

Thermal characteristics of reeled trailing cables for shuttle cars
Conference · Mon May 01 00:00:00 EDT 1995 · OSTI ID:41716

Operational characteristics of trailing cable splices
Conference · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:427893

Hope dims for SHD trailing cable
Journal Article · Tue Sep 01 00:00:00 EDT 1981 · Coal Age; (United States) · OSTI ID:6155987