Cyclic fatigue experiments and analysis of silicon nitrides -- stepwise loading
Journal Article
·
· Journal of Engineering Materials and Technology
- Torrington Co., CT (United States)
Rotating beam fatigue test has been performed at room temperature for two types of advanced hot-pressed silicon nitrides. The test completion modes consist of fast fracture, fatigue fracture, and runout (at about 10{sup 8} cycles). Some specimens tested have been subjected to step-up load testing. Application of Weibull statistical method has been made as the fatigue lives of specimens under a constant bending load are subjected to wide scatter. A maximum likelihood analysis was applied to test data obtained from the single load and step-up load tests to determine the fatigue (or crack growth) exponent. The effect of specimen surface finish on fast and fatigue fracture has also been investigated using the Weibull analysis.
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 289468
- Journal Information:
- Journal of Engineering Materials and Technology, Journal Name: Journal of Engineering Materials and Technology Journal Issue: 4 Vol. 120; ISSN 0094-4289; ISSN JEMTA8
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cyclic fatigue of silicon nitrides
Cyclic fatigue behavior and fracture toughness of silicon nitride ceramics sintered with rare-earth oxides
Response of resin transfer molded (RTM) composites under reversed cyclic loading
Conference
·
Tue Aug 01 00:00:00 EDT 1989
· Ceramic Engineering and Science Proceedings; (USA)
·
OSTI ID:6861946
Cyclic fatigue behavior and fracture toughness of silicon nitride ceramics sintered with rare-earth oxides
Journal Article
·
Thu Sep 01 00:00:00 EDT 1994
· Acta Metallurgica et Materialia; (United States)
·
OSTI ID:6916967
Response of resin transfer molded (RTM) composites under reversed cyclic loading
Journal Article
·
Sun Dec 31 23:00:00 EST 1995
· Journal of Engineering Materials and Technology
·
OSTI ID:203571