NRC confirmatory AP600 safety system phase I testing in the ROSA/AP600 test facility
The NRC confirmatory phase I testing for the AP600 safety systems has been completed in the modified ROSA (Rig of Safety Assessment) test facility located at the Japan Atomic Energy Research Institute (JAERI) campus in Tokai, Japan. The test matrix included a variety of accident scenarios covering both design and beyond-design basis accidents. The test results indicate the AP600 safety systems as reflected in ROSA appear to perform as designed and there is no danger of core heatup for the accident scenarios investigated. In addition, no detrimental system interactions nor adverse effects of non-safety systems on the safety system functions were identified. However, three phenomena of interest have been identified for further examination to determine whether they are relevant to the AP600 plant. Those three phenomena are: (1) a potential for water hammer caused by rapid condensation which may occur following the actuation of the automatic depressurization system (ADS), (2) a large thermal gradient in the cold leg pipe where cooled water returns from the passive residual heat removal system and forms a thermally stratified layer, and (3) system-wide oscillations initiating following the ADS stage 4 actuation and persisting until the liquid in the pressurizer drains and steam generation in the core becomes insignificant.
- Research Organization:
- Nuclear Regulatory Commission, Washington, DC (United States). Office of Nuclear Regulatory Research; Brookhaven National Lab., Upton, NY (United States)
- OSTI ID:
- 269716
- Report Number(s):
- NUREG/CP--0149-Vol.1; CONF-9510156--Vol.1; ON: TI96009154
- Country of Publication:
- United States
- Language:
- English
Similar Records
ROSA-AP600 characterization tests and analysis of 1-inch cold leg break test
ROSA/AP600 testing: Facility modifications and initial test results
Comparative Study of Station Blackout Counterpart Tests in APEX and ROSA/AP600
Conference
·
Sat Oct 01 00:00:00 EDT 1994
·
OSTI ID:54604
ROSA/AP600 testing: Facility modifications and initial test results
Conference
·
Sat Oct 01 00:00:00 EDT 1994
·
OSTI ID:54603
Comparative Study of Station Blackout Counterpart Tests in APEX and ROSA/AP600
Journal Article
·
Mon May 15 00:00:00 EDT 2000
· Nuclear Technology
·
OSTI ID:20822160