Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Sensitivity measurements for a 250 MHz quartz shear-horizontal surface acoustic wave biosensor under liquid viscous loading (in EN)

Journal Article · · AIP Advances
DOI:https://doi.org/10.1063/5.0166035· OSTI ID:2578393

Surface acoustic wave (SAW) devices have been used in biochemical assays due to their high sensitivity. The device sensitivity is a function of changes in the density and viscosity of the liquid. Here, we studied the effect of fluid viscosity using a 250 MHz quartz shear-horizontal (SH)-SAW biosensor by monitoring different concentrations of binary aqueous/glycerol solutions. In this study, the sensitivity of the biosensor was determined by fitting the data to models derived from perturbation theory. Measurements in water were used as the reference. For a 0% to 50% glycerol solution, an 87°–204° separation in the phase shift was observed. The slope of the plot of the phase shift vs (ηρ)0.5 was used to indicate the sensor’s sensitivity. The sensitivity for our 250 MHz quartz SH-SAW sensors was calculated to be 3.7×10−3m2sKg. The corresponding mass sensitivity was determined to be 9.25 × 105m2Kg. The limit of detection was calculated to be 36 picograms (pg), while the limit of quantification or LOQ was calculated to be 109 pg. Traditionally, liquid phase measurements have been challenging for SAW devices because liquids dampen the vibrating sensors severely. This problem has been largely solved using a transverse (shear) wave instead of the more popular longitudinal or Rayleigh waves. Liquid measurements are now possible using transverse waves, also known as shear waves, because transverse waves are only minimally attenuated by liquids. Shear-horizontal SAW sensors (SH-SAW) show great promise as label-free biosensors because of their ability to handle liquid samples. However, the viscosity of the liquid still induces loading effects and can be measured when the liquid is loaded onto the SH-SAW propagating surface (delay line). When the liquid above the delay line is perturbed by physical or chemical changes, such as binding to a receptor, it alters the propagating acoustic wave. The SH-SAW device can measure these changes in liquid properties as a change in the wave’s phase compared to the original wave. The device’s phase shift was recorded as a function of the changes in the density and viscosity of the binary glycerol solution and used to determine the sensitivity in the linear dynamic range of responses.

Research Organization:
Tennessee State Univ., Nashville, TN (United States)
Sponsoring Organization:
USDOE Office of Environmental Management (EM)
Grant/Contract Number:
EM0005266
OSTI ID:
2578393
Journal Information:
AIP Advances, Journal Name: AIP Advances Journal Issue: 12 Vol. 13; ISSN 2158-3226
Publisher:
American Institute of Physics (AIP)Copyright Statement
Country of Publication:
United States
Language:
EN

Similar Records

SH-SAW Sensor Platform for Chemical Detection in Aqueous Solutions
Conference · Tue Jul 20 00:00:00 EDT 1999 · OSTI ID:9630

Micromachined chemical sensor with integrated microelectronics
Conference · Wed Dec 30 23:00:00 EST 1992 · OSTI ID:10152257

Micromachined chemical sensor with integrated microelectronics
Conference · Tue Dec 31 23:00:00 EST 1991 · OSTI ID:6474557