Individual and Simultaneous Imaging of ⁹⁹mTc and ¹⁷⁷Lu With a Preclinical Broad Energy-Spectrum CZT-Based SPECT
Journal Article
·
· IEEE Transactions on Radiation and Plasma Medical Sciences
Radiopharmaceutical therapy has demonstrated a high efficacy in the treatment of various tumor types. One of the radionuclides already used in the clinic is 177Lu, a beta emitter that also emits several photons imageable with SPECT. Quantitative imaging of 177Lu is critical for developing new radiopharmaceuticals. Energy resolution is an important factor when imaging multiple photon emissions. Solid-state detectors offer a superior performance over scintillators, that are commonly used in commercially-available preclinical SPECT scanners. This study demonstrates the feasibility of 99m Tc and 177Lu quantitative imaging in mouse phantoms, individually and simultaneously, with a SPECT prototype built with four CdZnTe (CZT) detector heads and a custom-designed and energy-optimized parallel-hole tungsten collimator. With a custom implementation of the one-step late (OSL) image reconstruction algorithm, the system is capable of imaging energies from ~70 keV to 250 keV. Above 250 keV, images were significantly affected by septal penetration, consistent with the collimator design. A recovery coefficient within 25% was obtained for activities as low as 2 kBq/mL for 99m Tc and 45% for 177Lu. Compared to a commercial NaI-based preclinical SPECT (VECTor4/CT), our prototype showed a superior energy resolution (< 5% at 140 keV), a similar uniformity with a high-compact design.
- Research Organization:
- Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)
- Sponsoring Organization:
- US Department of Energy; USDOE Office of Science (SC), Nuclear Physics (NP) (SC-26)
- Grant/Contract Number:
- AC02-05CH11231
- OSTI ID:
- 2571782
- Journal Information:
- IEEE Transactions on Radiation and Plasma Medical Sciences, Journal Name: IEEE Transactions on Radiation and Plasma Medical Sciences Journal Issue: 5 Vol. 9
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pinhole SPECT: An approach to in vivo high resolution SPECT imaging in small laboratory animals
Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99mTc and 177Lu
Which collimator for SPECT with I-123 and CU-67
Journal Article
·
Mon Jan 31 23:00:00 EST 1994
· Journal of Nuclear Medicine Technology
·
OSTI ID:135840
Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99mTc and 177Lu
Journal Article
·
Mon Mar 13 20:00:00 EDT 2023
· Medical Physics
·
OSTI ID:2204143
Which collimator for SPECT with I-123 and CU-67
Conference
·
Sat Dec 31 23:00:00 EST 1983
· J. Nucl. Med.; (United States)
·
OSTI ID:6931204