A calibration of the IUCF K600 focal plane polarimeter

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.48849· OSTI ID:254033
; ; ; ; ; ; ; ; ;  [1]
  1. Indiana University Cyclotron Facility, Bloomington, Indiana 47408 (United States)
We have carried out a precise determination of the effective analyzing power of the K600 focal plane polarimeter at IUCF for incident proton energies extending from 200 MeV down to 120 MeV. Two different calibration techniques, and several analyzer thicknesses, were used over this range. As the energy decreases, the effective analyzing power falls almost linearly. The polarimeter efficiency, however, rises rapidly, thus maintaining a reasonable figure-of-merit. {copyright} {ital 1995 American Institute of Physics.}
Sponsoring Organization:
USDOE
OSTI ID:
254033
Report Number(s):
CONF-9409103--
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 343; ISSN 0094-243X; ISSN APCPCS
Country of Publication:
United States
Language:
English

Similar Records

The IUCF/TUNL spin-filter polarimeter
Journal Article · Fri Sep 01 00:00:00 EDT 1995 · AIP Conference Proceedings · OSTI ID:254074

Calibration of a neutron polarimeter
Journal Article · Sun Oct 01 00:00:00 EDT 1995 · Bulletin of the American Physical Society · OSTI ID:255536

Physics with a focal plane proton polarimeter for hall A at CEBAF