Plugging temperature indicator computer simulation
Conference
·
OSTI ID:238572
The Experimental Breeder Reactor 2 (EBR-2) is a sodium-cooled nuclear reactor with thermal and electrical outputs of 62 and 20 megawatts, respectively. EBR-2 has plugging temperature indicators (PTIs) in the sodium coolant system to measure the temperature that impurities will precipitate from the coolant. High plugging temperatures are undesirable because impurities can precipitate in cold reactor piping and inhibit sodium flow. Reading a plugging temperature accurately from a typical plugging run is important. A computer simulation program performs simulated plugging runs to optimize PTI operation. The simulation program also assisted electrical engineers in designing and testing a new PTI control system in their computer development laboratory.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 238572
- Report Number(s):
- ANL/TP/SUMM--88932; CONF-9606116--39; ON: DE96010770
- Country of Publication:
- United States
- Language:
- English
Similar Records
Plugging temperature indicator computer simulation
EBR-II secondary sodium loop Plugging Temperature Indicator control system upgrade
SELECTED DATA AND DISCUSSION OF THE PLUGGING INDICATOR FOR SODIUM LOOPS.
Journal Article
·
Mon Dec 30 23:00:00 EST 1996
· Transactions of the American Nuclear Society
·
OSTI ID:436894
EBR-II secondary sodium loop Plugging Temperature Indicator control system upgrade
Conference
·
Thu Jun 01 00:00:00 EDT 1995
·
OSTI ID:88481
SELECTED DATA AND DISCUSSION OF THE PLUGGING INDICATOR FOR SODIUM LOOPS.
Technical Report
·
Wed Dec 31 23:00:00 EST 1969
·
OSTI ID:4085572