Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Journal Article · · Analytical and Bioanalytical Chemistry
Abstract

High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution.

Graphical abstract

Sponsoring Organization:
USDOE
Grant/Contract Number:
SC0022207
OSTI ID:
2377775
Journal Information:
Analytical and Bioanalytical Chemistry, Journal Name: Analytical and Bioanalytical Chemistry Journal Issue: 25 Vol. 416; ISSN 1618-2642
Publisher:
Springer Science + Business MediaCopyright Statement
Country of Publication:
Germany
Language:
English

References (28)

Lipidomics in Biomarker Research book August 2021
Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead journal September 2019
High-defined quantitative snapshots of the ganglioside lipidome using high resolution ion mobility SLIM assisted shotgun lipidomics journal February 2021
Analysis of unsaturated lipids by ozone-induced dissociation journal November 2011
Lipid-based biomarkers for CVD, COPD, and aging – A translational perspective journal April 2020
Using SLIM-Based IMS-IMS Together with Cryogenic Infrared Spectroscopy for Glycan Analysis journal May 2020
Evaluation of Collision Cross Section Calibrants for Structural Analysis of Lipids by Traveling Wave Ion Mobility-Mass Spectrometry journal July 2016
Investigation of the Complete Suite of the Leucine and Isoleucine Isomers: Toward Prediction of Ion Mobility Separation Capabilities journal December 2016
Ion Mobility Collision Cross Section Compendium journal December 2016
Serpentine Ultralong Path with Extended Routing (SUPER) High Resolution Traveling Wave Ion Mobility-MS using Structures for Lossless Ion Manipulations journal April 2017
An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements journal August 2017
Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry journal October 2017
Determining Double Bond Position in Lipids Using Online Ozonolysis Coupled to Liquid Chromatography and Ion Mobility-Mass Spectrometry journal January 2018
Untargeted Molecular Discovery in Primary Metabolism: Collision Cross Section as a Molecular Descriptor in Ion Mobility-Mass Spectrometry journal November 2018
Effective Liquid Chromatography–Trapped Ion Mobility Spectrometry–Mass Spectrometry Separation of Isomeric Lipid Species journal February 2019
A Cyclic Ion Mobility-Mass Spectrometry System journal May 2019
Resolving Power and Collision Cross Section Measurement Accuracy of a Prototype High-Resolution Ion Mobility Platform Incorporating Structures for Lossless Ion Manipulation journal March 2021
Collision Cross-Section Calibration Strategy for Lipid Measurements in SLIM-Based High-Resolution Ion Mobility journal June 2022
Trapped Ion Mobility Spectrometry, Ultraviolet Photodissociation, and Time-of-Flight Mass Spectrometry for Gas-Phase Peptide Isobars/Isomers/Conformers Discrimination journal June 2022
Investigating Performance of the SLIM-Based High Resolution Ion Mobility Platform for Separation of Isomeric Phosphatidylcholine Species journal September 2023
Ion mobility conformational lipid atlas for high confidence lipidomics journal February 2019
Broadscale resolving power performance of a high precision uniform field ion mobility-mass spectrometer journal January 2015
Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry journal January 2016
Automated flow injection method for the high precision determination of drift tube ion mobility collision cross sections journal January 2018
Collision cross section compendium to annotate and predict multi-omic compound identities journal January 2019
Advanced Multidimensional Separations in Mass Spectrometry: Navigating the Big Data Deluge journal June 2016
A comprehensive classification system for lipids journal February 2005
Update of the LIPID MAPS comprehensive classification system for lipids journal December 2008

Similar Records

Lipid and glycolipid isomer analyses using ultra-high resolution ion mobility spectrometry separations
Journal Article · Tue Jan 17 19:00:00 EST 2017 · International Journal of Molecular Sciences (Online) · OSTI ID:1347858

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis
Journal Article · Sun Jun 11 20:00:00 EDT 2023 · Analytical Chemistry · OSTI ID:1994855

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations
Journal Article · Thu Feb 08 19:00:00 EST 2024 · Analytical Chemistry · OSTI ID:2429578

Related Subjects