Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Other ·
OSTI ID:2373028

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Research Organization:
Clemson University
Sponsoring Organization:
USDOE Office of Fossil Energy and Carbon Management (FECM)
DOE Contract Number:
FE0028292
OSTI ID:
2373028
Country of Publication:
United States
Language:
English

Similar Records

Using Strain in the Vadose Zone During Sinusoidal-Rate Well Tests to Characterize an Aquifer
Conference · Tue Dec 08 23:00:00 EST 2020 · OSTI ID:2373037

Evaluation of Zero-Net-Rate Pumping Tests
Other · Tue May 02 00:00:00 EDT 2023 · OSTI ID:2373029

Characterizing the Subsurface Using Deformation from Pumping and Surface Loading Tests
Conference · Tue Dec 11 23:00:00 EST 2018 · OSTI ID:2373041

Related Subjects