Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Testing of Microchannels and Lab-Grown Stress Corrosion Cracks for Quantification of Aerosol Transmission

Technical Report ·
DOI:https://doi.org/10.2172/2369610· OSTI ID:2369610
 [1];  [1];  [1];  [1]
  1. Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using higher backfill pressures in the canister, up to approximately 800 kPa, compared to their horizontal counterparts. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO2, were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to add to previous testing that characterized SCCs under well-controlled boundary conditions through the inclusion of testing improvements that establish initial conditions in a more consistent way. While the engineered microchannel has dimensions similar to actual SCCs, it does not reproduce the tortuous path the aerosol laden flow would have to traverse for eventual transmission. SCCs can be rapidly grown in a laboratory setting given the right conditions, and initial characterization and clean-flow testing has begun on lab grown crack samples provided to Sandia National Laboratories (SNL). Many such samples are required to produce statistically relevant transmission results, and SNL is developing a procedure to produce samples in welded steel plates. These ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

Research Organization:
Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA); USDOE Office of Nuclear Energy (NE), Office of Spent Fuel and Waste Disposition
DOE Contract Number:
NA0003525
OSTI ID:
2369610
Report Number(s):
SAND--2023-08375R
Country of Publication:
United States
Language:
English

Similar Records

Quantification of Aerosol Transmission through Stress Corrosion Crack-Like Geometries
Technical Report · Fri Aug 19 00:00:00 EDT 2022 · OSTI ID:1884914

Estimation of Respirable Aerosol Release Fractions through Stress Corrosion Crack-Like Geometries
Technical Report · Sat Aug 01 00:00:00 EDT 2020 · OSTI ID:1657656

Continued Investigations of Respirable Release Fractions for Stress Corrosion Crack-Like Geometries
Technical Report · Thu Jul 29 00:00:00 EDT 2021 · OSTI ID:1817839