Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Precursor and Neutral Loss Scans in an RF Scanning Linear Quadrupole Ion Trap

Journal Article · · Journal of the American Society for Mass Spectrometry

Methodology for performing precursor and neutral loss scans in an RF scanning linear quadrupole ion trap is described and compared to the unconventional ac frequency scan technique. In the RF scanning variant, precursor ions are mass selectively excited by a fixed frequency resonance excitation signal at low Mathieu q while the RF amplitude is ramped linearly to pass ions through the point of excitation such that the excited ion’s m/z varies linearly with time. Ironically, a nonlinear ac frequency scan is still required for ejection of the product ions since their frequencies vary nonlinearly with the linearly varying RF amplitude. In the case of the precursor scan, the ejection frequency must be scanned so that it is fixed on a product ion m/z throughout the RF scan, whereas in the neutral loss scan, it must be scanned to maintain a constant mass offset from the excited precursor ions. Both simultaneous and sequential permutation scans are possible; only the former are demonstrated here. The scans described are performed on a variety of samples using different ionization sources: protonated amphetamine ions generated by nanoelectrospray ionization (nESI), explosives ionized by low-temperature plasma (LTP), and chemical warfare agent simulants sampled from a surface and analyzed with swab touch spray (TS). We lastly conclude that the ac frequency scan variant of these MS/MS scans is preferred due to electronic simplicity. In an accompanying manuscript, we thus describe the implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 using constant RF voltage. .

OSTI ID:
22776896
Journal Information:
Journal of the American Society for Mass Spectrometry, Journal Name: Journal of the American Society for Mass Spectrometry Journal Issue: 7 Vol. 29; ISSN 1044-0305; ISSN JAMSEF
Country of Publication:
United States
Language:
English

Similar Records

Single Analyzer Precursor Ion Scans in a Linear Quadrupole Ion Trap Using Orthogonal Double Resonance Excitation
Journal Article · Fri Sep 15 00:00:00 EDT 2017 · Journal of the American Society for Mass Spectrometry · OSTI ID:22776906

Implementation of Precursor and Neutral Loss Scans on a Miniature Ion Trap Mass Spectrometer and Performance Comparison to a Benchtop Linear Ion Trap
Journal Article · Sun Jul 15 00:00:00 EDT 2018 · Journal of the American Society for Mass Spectrometry · OSTI ID:22776895

Ion remeasurement in the radio frequency quadrupole ion trap
Journal Article · Tue Nov 14 23:00:00 EST 1995 · Analytical Chemistry (Washington) · OSTI ID:159683