skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: X-ray optics testing beamline 1-BM at the advanced photon source

Abstract

Beamline 1-BM at the APS has been reconfigured in part for testing of synchrotron optics with both monochromatic and white beams. Operational since 2013, it was reconfigured to accommodate users of the APS as well as users from other DOE facilities. Energies between 6 and 28 keV are available. The beamline was reconfigured to remove two large mirrors and to provide a 100 mm wide monochromatic beam at 54 m from the source. In addition a custom white beam shutter was implemented for topography exposures as short as 65 millisec over the full available horizontal width. Primary agendas include both white beam and monochromatic beam topography, Talbot grating interferometry, and tests of focusing optics. K-B mirrors, MLLs, and FZPs have been characterized. Measurements of the spatial coherence lengths on the beamline were obtained with Talbot interferometry. Topography data has been reported.

Authors:
; ; ; ; ; ; ; ; ; ; ; ;  [1]
  1. Argonne National Laboratory, Argonne, IL 60439 (United States)
Publication Date:
OSTI Identifier:
22608366
Resource Type:
Journal Article
Journal Name:
AIP Conference Proceedings
Additional Journal Information:
Journal Volume: 1741; Journal Issue: 1; Conference: SRI2015: 12. international conference on synchrotron radiation instrumentation, New York, NY (United States), 6-10 Jul 2015; Other Information: (c) 2016 Author(s); Country of input: International Atomic Energy Agency (IAEA); Journal ID: ISSN 0094-243X
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ADVANCED PHOTON SOURCE; BEAMS; COHERENCE LENGTH; FOCUSING; INTERFEROMETRY; KEV RANGE; MONOCHROMATIC RADIATION; PHOTONS; SHUTTERS; SYNCHROTRONS; TOPOGRAPHY; X RADIATION

Citation Formats

Macrander, Albert, Erdmann, Mark, Kujala, Naresh, Stoupin, Stanislav, Marathe, Shashidhara, Shi, Xianbo, Wojcik, Michael, Nocher, Dan, Conley, Raymond, Sullivan, Joseph, Goetze, Kurt, Maser, Jorg, and Assoufid, Lahsen. X-ray optics testing beamline 1-BM at the advanced photon source. United States: N. p., 2016. Web. doi:10.1063/1.4952853.
Macrander, Albert, Erdmann, Mark, Kujala, Naresh, Stoupin, Stanislav, Marathe, Shashidhara, Shi, Xianbo, Wojcik, Michael, Nocher, Dan, Conley, Raymond, Sullivan, Joseph, Goetze, Kurt, Maser, Jorg, & Assoufid, Lahsen. X-ray optics testing beamline 1-BM at the advanced photon source. United States. doi:10.1063/1.4952853.
Macrander, Albert, Erdmann, Mark, Kujala, Naresh, Stoupin, Stanislav, Marathe, Shashidhara, Shi, Xianbo, Wojcik, Michael, Nocher, Dan, Conley, Raymond, Sullivan, Joseph, Goetze, Kurt, Maser, Jorg, and Assoufid, Lahsen. Wed . "X-ray optics testing beamline 1-BM at the advanced photon source". United States. doi:10.1063/1.4952853.
@article{osti_22608366,
title = {X-ray optics testing beamline 1-BM at the advanced photon source},
author = {Macrander, Albert and Erdmann, Mark and Kujala, Naresh and Stoupin, Stanislav and Marathe, Shashidhara and Shi, Xianbo and Wojcik, Michael and Nocher, Dan and Conley, Raymond and Sullivan, Joseph and Goetze, Kurt and Maser, Jorg and Assoufid, Lahsen},
abstractNote = {Beamline 1-BM at the APS has been reconfigured in part for testing of synchrotron optics with both monochromatic and white beams. Operational since 2013, it was reconfigured to accommodate users of the APS as well as users from other DOE facilities. Energies between 6 and 28 keV are available. The beamline was reconfigured to remove two large mirrors and to provide a 100 mm wide monochromatic beam at 54 m from the source. In addition a custom white beam shutter was implemented for topography exposures as short as 65 millisec over the full available horizontal width. Primary agendas include both white beam and monochromatic beam topography, Talbot grating interferometry, and tests of focusing optics. K-B mirrors, MLLs, and FZPs have been characterized. Measurements of the spatial coherence lengths on the beamline were obtained with Talbot interferometry. Topography data has been reported.},
doi = {10.1063/1.4952853},
journal = {AIP Conference Proceedings},
issn = {0094-243X},
number = 1,
volume = 1741,
place = {United States},
year = {2016},
month = {7}
}