Reproducibility of the cutoff probe for the measurement of electron density
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701 (Korea, Republic of)
- Plasma Technology Research Center, National Fusion Research Institute, Gunsan 573-540 (Korea, Republic of)
Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.
- OSTI ID:
- 22600142
- Journal Information:
- Physics of Plasmas, Vol. 23, Issue 6; Other Information: (c) 2016 Author(s); Country of input: International Atomic Energy Agency (IAEA); ISSN 1070-664X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurement of electron density using reactance cutoff probe
Cutoff probe using Fourier analysis for electron density measurement