Responsivity calibration of the LoWEUS spectrometer
Journal Article
·
· Review of Scientific Instruments
- Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)
We performed an in situ calibration of the relative responsivity function of the Long-Wavelength Extreme Ultraviolet Spectrometer (LoWEUS), while operating on the Lithium Tokamak Experiment (LTX) at Princeton Plasma Physics Laboratory. The calibration was accomplished by measuring oxygen lines, which are typically present in LTX plasmas. The measured spectral line intensities of each oxygen charge state were then compared to the calculated emission strengths given in the CHIANTI atomic database. Normalizing the strongest line in each charge state to the CHIANTI predictions, we obtained the differences between the measured and predicted values for the relative strengths of the other lines of a given charge state. We find that a 3rd degree polynomial function provides a good fit to the data points. Our measurements show that the responsivity between about 120 and 300 Å varies by factor of ∼30.
- OSTI ID:
- 22596393
- Journal Information:
- Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 11 Vol. 87; ISSN 0034-6748; ISSN RSINAK
- Country of Publication:
- United States
- Language:
- English
EUV Spectra and Line Ratios of Multiply Ionized Calcium and Argon Atoms in a Laboratory Plasma
|
journal | October 2018 |
Electron-density-sensitive Line Ratios of Fe xiii– xvi from Laboratory Sources Compared to CHIANTI
|
journal | February 2018 |
Similar Records
Responsivity calibration of the LoWEUS spectrometer
ABSOLUTE RADIOMETRIC CALIBRATION OF THE EUNIS-06 170-205 A CHANNEL AND CALIBRATION UPDATE FOR CORONAL DIAGNOSTIC SPECTROMETER/NORMAL-INCIDENCE SPECTROMETER
Calibration results of the ebit medium-energy flat-field spectrometer using the LBL advanced light source
Journal Article
·
Thu Sep 01 20:00:00 EDT 2016
· Review of Scientific Instruments
·
OSTI ID:1349666
ABSOLUTE RADIOMETRIC CALIBRATION OF THE EUNIS-06 170-205 A CHANNEL AND CALIBRATION UPDATE FOR CORONAL DIAGNOSTIC SPECTROMETER/NORMAL-INCIDENCE SPECTROMETER
Journal Article
·
Sun Jan 31 23:00:00 EST 2010
· Astrophysical Journal, Supplement Series
·
OSTI ID:21301330
Calibration results of the ebit medium-energy flat-field spectrometer using the LBL advanced light source
Technical Report
·
Tue Jan 16 23:00:00 EST 2001
·
OSTI ID:15006178