Title: Simulation of effects of direction and air flow speed on temperature distribution in the room covered by various roof materials

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4943443· OSTI ID:22590838
 [1]
  1. Mechanical Engineering Department, Sebelas Maret University, Surakarta, Indonesia 57126 (Indonesia)

The objective of this research is to get a comparison of the distribution of the room temperature by using three materials, namely plastic-rubber composite, clay, and asbestos. The simulation used Ansys Fluent to get the temperature distribution. There were two conditions in this simulations, first the air passing beside the room and second the air passing in front of the room. Each condition will be varied with the air speed of 1 m/s, 2 m/s, 3 m/s, 4 m/s, 5 m/s for each material used. There are three heat transfers in this simulation, namely radiation, convection, and conduction. Based on the ANSI/ ASHRAE Standard 55-2004, the results of the simulation showed that the best temperature distribution was the roof of plastic-rubber composites.

OSTI ID:
22590838
Journal Information:
AIP Conference Proceedings, Vol. 1717, Issue 1; Conference: ICE-SEAM 2015: 4. international conference and exhibition on sustainable energy and advanced materials 2015, Solo (Indonesia), 11-12 Nov 2015; Other Information: (c) 2016 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English