Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States)
- Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States)
Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.
- OSTI ID:
- 22581364
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 9 Vol. 42; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
{ital In vivo} bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography
Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
The use of optical coherence tomography for morphological study of scaffolds
Journal Article
·
Mon Sep 01 00:00:00 EDT 1997
· Optics Letters
·
OSTI ID:560688
Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
Journal Article
·
Fri Jan 14 23:00:00 EST 2000
· Optics Letters
·
OSTI ID:20215184
The use of optical coherence tomography for morphological study of scaffolds
Journal Article
·
Thu May 31 00:00:00 EDT 2012
· Quantum Electronics (Woodbury, N.Y.)
·
OSTI ID:22043959