SU-E-T-17: A Comparison of Forward and Field in Field Intensity Modulation Radiotherapy Planning for Breast Cancer
- shandong tumor hospital, Jinan, Shandong (China)
Purpose: To compare the dosimetric difference in forward intensity modulation radiotherapy(fIMRT) and field in field IMRT (FIF IMRT)planning for breast cancer. Methods: Ten patients received radiotherapy are selected.For each patient,two treatment plans(fIMRT and FIF IMRT) were designed with Varian Eclipse ver11.0 treatment planning system.Evaluate the dose parameters of targets, organs at risk (OAR), monitor units and treatment time, using dose-volume histogram (DVH). Results: There were no significant difference were found in conformal index (CI), homogeneity index (HI) of PTV,V5,V10,V20,V30,V40,V50 of heart, lung and monitor unit(MU)(P>0.05).The differences were significant in the treatment time(fIMRT=8.3min,FIF IMRT=2.5,p<0.05). Conclusion: FIF IMRT is equal to fIMRT in dosimetril evaluation. Due to much less delivery time,FIF IMRT is an efficient technique in treating patients by reduceing the uncomfortable influnce which could effect the treatment.
- OSTI ID:
- 22545152
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 42; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
SU-E-T-810: Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Non-Small-Cell Lung Cancer with Simultaneously Integrated Boost Radiation Therapy: A Planning Comparison Study
SU-E-T-311: Dosimetric Comparison of Volumetric Modulated Arc Therapy Plans for Preoperative Radiotherapy Rectal Cancer Using Flattening Filter-Free and Flattening Filter Modes
SU-E-P-51: Dosimetric Comparison to Organs at Risk Sparing Using Volumetric-Modulated Arc Therapy Versus Intensity-Modulated Radiotherapy in Postoperative Radiotherapy of Left-Sided Breast Cancer
Journal Article
·
Mon Jun 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:22555174
SU-E-T-311: Dosimetric Comparison of Volumetric Modulated Arc Therapy Plans for Preoperative Radiotherapy Rectal Cancer Using Flattening Filter-Free and Flattening Filter Modes
Journal Article
·
Mon Jun 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:22548367
SU-E-P-51: Dosimetric Comparison to Organs at Risk Sparing Using Volumetric-Modulated Arc Therapy Versus Intensity-Modulated Radiotherapy in Postoperative Radiotherapy of Left-Sided Breast Cancer
Journal Article
·
Mon Jun 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:22486699